BHD Series:
Model Working
Volume
Dimensions
H x W x D
Temperature
Range
Rise
Time
Pull Down
Time
Humidity
Range
Power
Requirements
Download
Brochure
BHD-403 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-17°C to +177°C
-0°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-405 5 Cubic Ft. Internal
20" x 20" x 22"
External
32" x 49" x 32"
-17°C to +177°C
-0°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-408 8 Cubic Ft. Internal
24" x 24" x 24"
External
34" x 53" x 34"
-17°C to +177°C
-0°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 25 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-503 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-37°C to +177°C
-35°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 35 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-505 5 Cubic Ft. Internal
20" x 20" x 22"
External
32" x 49" x 32"
-37°C to +177°C
-35°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 35 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-508 8 Cubic Ft. Internal
24" x 24" x 24"
External
34" x 53" x 34"
-37°C to +177°C
-35°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 35 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-203 3 Cubic Ft. Internal
16" x 20" x 18"
External
28" x 49" x 28"
-65°C to +177°C
-85°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 70 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-205 5 Cubic Ft. Internal
20" x 20" x 22"
External
32" x 49" x 32"
-65°C to +177°C
-85°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 70 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open
BHD-208 8 Cubic Ft. Internal
24" x 24" x 24"
External
34" x 53" x 34"
-65°C to +177°C
-85°F to +350°F
Room ambient to upper limit in approx. 20 minutes Room ambient to lower limit in approx. 70 minutes 20% to 98%
±2% RH
limited by +2°C dew point
1 Phase
220 Volt
60 Hz.
1 Phase
200 Volt
50 Hz.
Click to Open

 

Standard Features Optional Extras

 

 

 
Contact us at (978) 772-0022 or Sales@associatedenvironmentalsystems.com