FD-501 Model is a floor-style temperature-only environmental test chamber. 

STRUCTURE.  The internal workspace is lined with type 304 stainless steel for a vapor-tight internal construction. The exterior has a durable powder-coat finish over heavy-gauge steel for a long-lasting clean look. Between the two layers is highly-efficient, low k-factor, thermal insulation. This chamber is built to last for many years.

CIRCULATION SYSTEM.  Air circulation is crucial for environmental testing. The FD-501 Test Chamber has a proprietary baffle and fan design combination. This optimizes temperature conditions within the workspace. 

HEATING SYSTEM.  FD test chambers feature heating systems equipped with open ceramic-core nichrome heaters for reliable and accurate temperature control within ±0.5°C.

COOLING SYSTEM. The cooling system in the is FD-501 consists of a self-contained, compact, single-stage, mechanical refrigeration system with an air-cooled condenser. An optional water cooling condenser is available.

Add boost cooling with liquid LN2 or CO2 to shorten pull-down times; it's a great option for stress tests that require rapid cooling.

INSTRUMENTATION.  FD Series Test Chambers have incorporated the AESONE CONNECT creating a robust connected device for a standard and uniform interface making operation easier. Learn more in the Instrumentation Tab below.

ALTERNATIVE TEMPERATURE RANGES:

  • FD-201-65°C to 180°C (-85°F to 356°F)

 

Contact us for quote
Show More...
  • Specifications
  • Standard Features
  • Instrumentation
  • Safety Features
  • Optional Features
  • Downloads

Specifications

Interior: 13.5W x 16D x 9H (in)
  34.5W x 40.5D x 23H (mm)
Exterior: 19.5"W x 32"D x 41"H (in)
  495.3W x 812.8D x 1041.4H (cm)
Volume: 1.125 cubic ft
  31.86 liters
Temperature: -37°C to 180°C (-35°F to 356°F)
Rise Rate*: 3.88
Pull Down Rate*: 1.38
Electrical Supply:  120VAC, 1PH, 50HZ or 60HZ,
Full Load Amps: 15A
Power Requirement: NEMA 5-15
Mobility: Will fit through 32" door

*Rise and pull-down rates calculated using IEC 60068-3-5 standard. Custom options available.

Specifications

  • Interior Cabinet: Stainless Steel, Type 304
  • Exterior Cabinet: Cold Rolled Steel, Heavy-Gauge, Powder Coat finish, Color: Bone
  • 8 x 8 in. Multipane Viewing Window
  • Heated Window (Standard on -65°C Models Only)
  • Internal Light with External Switch
  • Port Configuration: Left Wall Access Port and Plug with 3 in. (76.2mm) Diameter
  • Locking Swivel Casters, set of 4

Instrumentation

STANDARD INSTRUMENTATION

CONTROLLER

FD Series Test Chambers have incorporated AESONE CONNECT creating a robust connected device for a standard and uniform interface making test chamber operation easier.

AESONE XCHANGE increases your functionalityaesone-connect-1

  • connects the test chamber controller to your network for increased accessibility
  • on-board multi-year data logging

AESONE SOFTWARE gives you the power to

  • remote chamber operation and monitoring, 
  • web-based test profile creation, 
  • viewing current data and historical data visually
  • secure multi-level user access 

ADDITIONAL ONBOARD INSTRUMENTATION

WATLOW F4T PROGRAMMABLE CONTROLLER. Features a 4.3” capacitive touchscreen minimizing the chance for error. Ethernet communication supported by AESONE HARDWARE. View more controller options

SENSORS. 100 OHM Platinum RTD  is a highly-accurate sensor made from platinum components for increased sensitivity View sensor options

OPTIONAL DATA LOGGERS. View additional data loggers

Safety Features

  • Adjustable Digital Set Limit Controller Indicating High-Temperature Safety
  • Over Temperature Heat Fusing
  • Refrigeration System Over Pressure Safety Circuit
  • TUV Rheinland Certified Meeting UL 61010-1, US, C, E

Optional Features

  • Shelf Modification (placement, size, number)
  • Custom Porting Sizes
  • Custom window size
  • Noise Reduction Package
  • LN2 Boost Cool
  • CO2 Boost Cool
  • Desiccant Air Dryer to ensure conditions as low as 5% RH
  • Dry Nitrogen Purge to keep condensation and frost from accumulating on DUT surfaces at cold temperatures and to prevent oxidation of metals surfaces at high temperatures